Part Number Hot Search : 
A3964 50N06 10SB4 RF2043 50N06 FL1523 PI3USB40 EF9367C
Product Description
Full Text Search
 

To Download XFPM-100KPGVR Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Pre-amplified/5V Excitation/Gauge
Features
. . . . . Two accuracy ranks, 1.5 FS and 2.5 FS available Volt level output On-chip amplification and temperature compensations Pre-calibration of offset voltage and span Non-corrosive liquid measurable (XFPMC, XFHMC only)
XFPM,XFHM Data sheet
Applications
. Industrial instrumentation . Pressure switch, Pneumatic device . Medical device
Part number for ordering
XFPM C - 025KP G R H
Accuracy No mark : H : Model XFPM XFHM Rated pressure (Pa) Available pressure media No mark : Non-corrosive gas only Pressure type C : Non-corrosive gas and liquid G : Gauge (Positive pressure) (Contact us about availability) GV : Gauge (Negative pressure) GW : Gauge (Bipolar pressure)
Pressure type XFPM Gauge pressure XFHM
2.5 FS 1.5 FS (Contact us about availability) Terminal leads direction (See Outline Diagram) No mark : R :
Model
Package configuration Measurable pressure range (kPa) 100 100 0 100 0 25 0 50 0 100 0 200 0 1000
Dual-In-line-Package (DIP) Part number for ordering XFPM-100KPGWR XFPM-100KPGVR XFPM-025KPGR XFPM-050KPGR XFPM-100KPGR XFPM-200KPGR XFPM-001MPGR
Horizontal pressure port DIP
XFPM-100KPGW XFPM-100KPGV XFPM-025KPG XFPM-050KPG XFPM-100KPG XFPM-200KPG XFPM-001MPG
XFHM-100KPGWR XFHM-100KPGVR XFHM-025KPGR XFHM-050KPGR XFHM-100KPGR XFHM-200KPGR XFHM-001MPGR
Specifications
Model/Rated pressure 100KPGW 100KPGV 025KPG 050KPG 100KPG 200KPG 001MPG
Unit
Recommended operating conditions Pressure type Gauge pressure 100 100 25 50 100 200 1000 Rated pressure 1.020 1.020 0.255 0.510 1.020 2.040 10.20 Measurable pressure range 100 100 0 100 0 25 0 50 0 100 0 200 0 1000 Pressure media 1 XFPM, XFHM : Non-corrosive gas only, XFPMC, XFHMC : Non-corrosive gas and liquid Excitation voltage 5.0 0.25 Absolute maximum rating 1.5times of rated pressure Maximum load pressure Twice of rated pressure Maximum excitation voltage 8 Operating temperature 40 125 Storage temperature 40 125 Operating humidity 30 80 (No dew condensation) Electric performances/characteristics(Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25 ) Current consumption less than 10 Output impedance less than 10 Source current less than 0.2 Sink current less than 2 Mechanical response time 2 (For the reference) Full scale span voltage 4.5 Offset voltage 1.2 0.2 0.1125, 0.2 0.0675(H) Full scale span voltage 1.2 4.7 0.1125, 4.7 0.0675(H) Accuracy 1.2 2.5, 1.5(H)
Note ; 1) Please consult us available when you choose the C models and the H models. 2) Excluding input voltage error.
kPa kg/cm2 kPa VDC
VDC
RH mA mA mA msec V V V FS/0 85
1
Pre-amplified/5V Excitation/Gauge
Outline dimensions
XFPM,XFHM Data sheet
unit : mm
XFPM
12 0.5 6 5 4 4 2.2 8
5 0.2
max 15
Pressure port 0.8 0.6 Vent hole
4.5 4 5 6
15.24(600mil)
R1.5 3 C0.5
14
1
2
3 Terminal leads
3
2
1
Labelled faceplate
6.8 2.8
Recommended footprint for PCB
6- 0.9(Diameter of through holes)
2.54 2.54
6- 1.8(Diameter of lands)
1.2
60
15.2
(unit : mm)
unit : mm
XFPM-R
0.2
12
max 15
4 0.5 2.2
8
5
6
5
4
0.8 Pressure port
4
5
6
R1.5 14 3
C0.5 1 2 3 Terminal leads Labelled faceplate 0.6 Vent hole 32 4.5 1
0.5
15.24(600mil)
2.54 2.54
Recommended footprint for PCB
6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands)
1.2
60
2.8 6.8
15.2
(unit : mm)
2
2.54 2.54
2.54 2.54
0.5
Pre-amplified/5V Excitation/Gauge
Outline dimensions
XFPM,XFHM Data sheet
XFHM-R
1
2.54 2.54 2 3
unit : mm
Pressure port
6
5
4
(14) 1.2
1
3.2
1.55 2.6 6 0.6 4.7
5.5
15
10.16
0.25
Vent hole
3.4 (7.6)
Labelled faceplate
8 6 5 4
Recommended footprint for PCB
6- 1(Diameter of through holes) 6- 1.8(Diameter of lands)
8
1
2
3
10
(unit : mm)
3
2.54 2.54
1
Pre-amplified/5V Excitation/Gauge
Connection diagram XFPM, XFHM
Vcc
XFPM,XFHM Data sheet
Vcc(DC5V)
Vout Vout GND C2 C1
GND
Remarks : 1) C1 : Connect 680pF capacitor within 2cm distance from leads. 2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads. 3) 4 and 5 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or each other.
Transfer Function
Vout=Vs (P Vs=5.0volts
Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage.
+ ) (Pressure Error Temperature Error Multiplier
Vs)
P=Input Pressure(kPa)
Model 025KPG(D) 050KPG(D) 100KPG(D) 100KPGV 100KPGW(DW) 200KPG(D) 001MPG(D) 115KPA pressure range 0 25kPa 0 50kPa 0 100kPa 0 100kPa 100 +100kPa 0 200kPa 0 1MPa 15 115kPa.abs 0.036 0.018 0.009 0.009 0.0045 0.0045 0.0009 0.009 0.04 0.04 0.04 0.04 0.49 0.04 0.04 0.095 Pressure Error(kPa) 0.625 1.25 2.5 2.5 5.0 5.0 25 2.5
Temperature Error Multiplier
3.5
Temperature Error Multiplier
3 2.5 2 1.5 1 0.5 0 -40 85 125 120
-20
0
20
40 Temperature
60
80
100
Note ; Please read instruction "Notes" before using the sensor. Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 4 E-mail : sensor@fujikura.co.jp


▲Up To Search▲   

 
Price & Availability of XFPM-100KPGVR

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X